T2300 |
41:YZ |
Electrical Fault or current limit in Media-Axix Motor |
Turn off/on. Open scnner and check for visible obstacles. Perform paper drive diagnostic and rewinder diagnostic test, Check Media Advance drive cable, Repalce media advance, replace Engine PCA |
T1100 |
41:YZ |
Electrical fault or current limit in Media-Axis Motor.. |
Turnoff/on. Check fo visable obstacles restricting movement of Media advance roller, run Media Drive Diagnostics, Check Cables, replace Media Advance Drive or Main PCA |
T610 |
41:YZ |
Electrical fault or current limit in Media-Axis Motor.. |
Turn off/on. Check fo visable obstacles restricting movement of Media advance roller, run Media Drive Diagnostics, Check Cables, replace Media Advance Drive or Main PCA |
Z5200 |
41:YZ |
Electrical fault or current limit in Media-Axis Motor. |
Reboot. Check for Visable Obstacles , clear obstructions, perform paper drive diagnostic test, check cables, replace the Media Advance Drive, replace the Main PCA |