| Z6 |
0021-0002-0017 |
SVS motor movement blocked |
Reboot, Check service station path, remove visible obstacles, repalce Service station parts (SVS motor, transmission, shuttle) , replace Mechatronics PCA |
| Z9 |
0021-0002-0017 |
SVS motor movement blocked |
Reboot, Check service station path, remove visible obstacles, repalce Service station parts (SVS motor, transmission, shuttle) , replace Mechatronics PCA |
| T1700 |
0021-0002-0017 |
SVS motor movement blocked |
Reboot, Check service station path, remove visible obstacles, repalce Service station parts (SVS motor, transmission, shuttle) , replace Mechatronics PCA |
| T1600 |
0021-0002-0017 |
Electrical or mechanical issue with Service Station |
Restart, clear service station path, remove any visable obstacles, check cables to service station, replace if needed, run 02101 and 02102 diagnostics, replace service station |
| T2600 |
0021-0002-0017 |
Electrical or mechanical issue with Service Station |
Restart, clear service station path, remove any visable obstacles, check cables to service station, replace if needed, run 02101 and 02102 diagnostics, replace service station |