T1600 0086-0002-0010 The 5V signal generated in the Carriage PCA is not detected Clean the septum and electrical connections between the carriage PCA and the printhead. Re-insert the printhead for a second attempt to start up. Check that the firmware is the latest one, and check also if the printhead or carriage PCA are well placed in the Carriage structure. Check the orange 5V diagnostic LED (DS2) of the Carriage PCA. If the orange 5V diagnostic LED (DS2) is on, run the 08601 Checks Electronics service diagnostic and check if the 5V status is OK. If the 5V check status is OK, try using a new printhead. If the 5V check status failure is confirmed, replace the Carriage PCA. If the problem persists, replace the Trailing cable.
T2600 0086-0002-0010 The 5V signal generated in the Carriage PCA is not detected Clean the septum and electrical connections between the carriage PCA and the printhead. Re-insert the printhead for a second attempt to start up. Check that the firmware is the latest one, and check also if the printhead or carriage PCA are well placed in the Carriage structure. Check the orange 5V diagnostic LED (DS2) of the Carriage PCA. If the orange 5V diagnostic LED (DS2) is on, run the 08601 Checks Electronics service diagnostic and check if the 5V status is OK. If the 5V check status is OK, try using a new printhead. If the 5V check status failure is confirmed, replace the Carriage PCA. If the problem persists, replace the Trailing cable.