| T1600 |
0086-0005-0046 |
Line sensor cannot be calibrated |
Check the Line sensor cable to the Carriage PCA. Run the 08601 Checks Electronics service diagnostic. Run the Drop detector calibration Service utility. Replace the Line sensor. Replace the Carriage PCA. |
| T2600 |
0086-0005-0046 |
Line sensor cannot be calibrated |
Check the Line sensor cable to the Carriage PCA. Run the 08601 Checks Electronics service diagnostic. Run the Drop detector calibration Service utility. Replace the Line sensor. Replace the Carriage PCA. |